BF-40/BF-40-MM
Plc Blocking filters-single phase - BF-40/BF-40-MM
R.V (max): 275 Vac / R.C: 20-80A / Performance: Single&Double Stg
- Suitable for Smart meters which comply with PLC G3, PRIME & CENELEC Band A technology.
- Designed to meet according to EN 50065-1 regulations.-MM models, SP, SG3 models support reconnection mechanism.
- Safety terminals with double screws connection up to 60 Amps & Standard Safety Terminal blocks for 80 Amps.
Request a quote.
¥0.00
国内库存:0
西班牙库存:0
数量
-
+
件
请求报价
告诉我们您的需求,并在不到一天的时间 内得到我们专家的答复!
- 数据表
- 尺寸
- 包装
- 测试条件
- 平面布局
Length (mm) | 200 |
Height (mm) | 80 |
Width (mm) | 103 |
Operating Voltage (Max) | 250Vac (275Vac) |
Operating Frequency | 50 / 60 Hz |
Operating Current at ambient | 40A @ 40°C |
Supporting current for Hours & Min´s | 45A and 63A |
Operating Temperature Range | (-25ºC to +100ºC) |
Storage Temperature Range | (-25ºC to +85ºC) |
Filter Characterictics (CENELEC Band) | 9 to 150KHz (Band A,B,C,D) |
Attenuation Level ( mainly 35-90Khz) | 40 dB 20dB for MM |
High Surge Protection (Phase-Neu.) | 10000 A, 8/ 20µs |
MTBF at 25°C, 230Vac, 40A (ref.) | Minimum 20 years |
Dielectric strength | Phase-Housing 2.5KVac |
without surge protection | Phase-Neutral 1.7KVdc |
Leakage Current | Nil (no PE insisted) |
Installing in 3 Phase system | Max. Voltage P-P 480Vac |
Ingress Protection | IP 20 |
Mounting Style | Din-Rail 35 + Panel |
Safety Regulation Followed | EMC Directive 2004/108/EC, UL1283, EN60939-2, IEC 60950-1 RoHS 2011/65/EU |
Suitable for Compliance | EN 50065-1 |